ARS-LIGHT Smart Dual-Fan Heat Recovery Ventilator


Simple Control. Smart Functions. Reliable Performance.
ARS-LIGHT is a smart dual-fan heat recovery ventilator, operated with an exceptionally easy-to-use remote control.
Each command is confirmed by a short audible signal from the internal control module, so the user always knows the device has successfully received the instruction.
🔹 Automatic Heating & Protection Systems
The heat recovery unit is equipped with an integrated automatic heating element that:
protects the heat-accumulating ceramic core from freezing,
safeguards the entire system against overheating or potential fire risks.
All protection functions operate fully autonomously, requiring no user intervention.
🔹 Simple and Intuitive Remote Control
Top buttons:
LOW / MED / HI – three fan speed levels
STOP – fan stop
Central button – main system ON / OFF
Bottom buttons – delayed shut-off timer:
1H, 2H, 4H, 8H – after the selected time, the unit shuts down completely, leaving only the remote receiver active.
This is especially convenient for spaces that will not be used for some time after ventilation, such as saunas, entryways, holiday homes, or seasonal buildings.
🔹 Power-Up & Operating Logic
When the unit is connected to the power supply (~230 V):
a short audible signal is emitted,
fans remain in STOP mode,
frost protection is active even if the fans are not running.
When any fan speed is selected:
the supply air fan operates first for 3–4 minutes,
then the system switches to its standard cyclic operating mode.
🔹 Stable Operating Cycles
Fans operate alternately in fixed cycles:
Air supply: ~1 min 50 s
Air exhaust: ~1 min 40 s
These intervals remain constant regardless of speed settings, though they may vary slightly under extremely low or high mains voltage.
Fan power levels:
LOW: 5.5 W
MED: 10 W
HI: 18 W
At low voltage levels (<200 V), the fans may not start at the lowest speed.
🔹 Timer & Shutdown Logic
Once the ventilator is turned on, the timer (1–8 hours) can be activated.
When the timer expires:
the unit shuts down completely,
frost protection is also disabled.
To restart the device after timer shutdown, the user must:
press ON / OFF,
select LOW / MED / HI speed.
🔹 Automatic Safety Functions
Frost protection: activates and deactivates automatically based on the temperature of the heat recovery core. It does not operate if the unit is switched off via the timer or ON/OFF button.
Overheating protection: always active, regardless of whether the unit is operating.
🔹 Power Consumption
Maximum fan power: 18 W
Maximum heating element power: 21 W, reduced to 4 W once +80 °C is reached
Control electronics power consumption: 1 W
🔹 Installation & Electrical Connection
Recommended wiring:
Red wire – phase (L)
Black wire – neutral (N)
🔹 Unique Remote Control Pairing
Each remote control features a unique paired code and works only with its assigned device.
Other remotes are not compatible.
Dažniausiai užduodami
Kaip veikia minirekuperatorius?
Minirekuperatorius ištraukia iš patalpos blogą orą ir per keraminį šilumos ir drėgmės regeneratorių su impulsiniu pašildymu, akumuliuoja iš patalpos oro šilumą. Po to, paduoda iš lauko švarų orą ir grąžina šilumą.
Ar tinka Lietuvos klimatui?
Taip, mūsų minirekuperatorius sukurtas specialiai Lietuvos oro sąlygoms.
Kaip valdomas įrenginys?
Valdymas labai paprastas – naudojamas patogus pultelis, leidžiantis reguliuoti veikimą.
Kiek ventiliatorių yra įrenginyje?
Įrenginyje yra du jūriniai ventiliatoriai, užtikrinantys efektyvų oro srautą.
Ar įrenginys taupo energiją?
Taip, impulsinis pašildymas padeda sumažinti energijos suvartojimą.
Kokios yra pagrindinės minirekuperatoriaus savybės?
Naujos kartos konstrukcija, paprastas valdymas, efektyvus šilumos ir drėgmės atgavimas.
ARS LIGHT šilumos regeneratorius tikrai pagerino mūsų namų mikroklimatą – jauku ir šilta.
J. ir M.


★★★★★